| :: Hardness | Catalog: #693 | | Back to Top |
|
| One 250 mL Whole-Volume bottle is ready to analyze. Now includes sodium in the new EPA/NELAC required PT concentration range. Use with AA, ICP-OES, ICP-MS or titrimetric methods. |
| | | - Calcium hardness as
CaCO3
- Total hardness as
CaCO3
|
|
|
| :: Inorganics | Catalog: #698 | | Back to Top |
|
| One 500 mL Whole-Volume bottle is ready to analyze. Now includes alkalinity in the new EPA/NELAC required PT range. Also, includes sodium at an intentionally higher range than in the Hardness standard. |
| | - Alkalinity
- Chloride
- Conductivity
- Fluoride
- Nitrate as N
| - Nitrate + nitrite as N
- Potassium
- Sodium
- Sulfate
- Total Dissolved Solids at 180°C
|
|
|
| :: pH | Catalog: #779 | | Back to Top |
|
| One 250 mL Whole-Volume bottle is ready to analyze. Use with electrometric methods. |
|
|
| :: Metals | Catalog: #697 | | Back to Top |
|
| One 15 mL screw-top vial yields up to 2 liters after dilution. Use with AA, ICP-OES or ICP-MS methods. The Arsenic concentration will change in 2006 due to the new EPA Drinking Water regulation. |
| | - Aluminum
- Antimony
- Arsenic
- Barium
- Beryllium
- Boron
- Cadmium
- Chromium
- Copper
- Iron
| - Lead
- Manganese
- Molybdenum
- Nickel
- Selenium
- Silver
- Thallium
- Vanadium
- Zinc
|
|
|
| :: Mercury | Catalog: #666 | | Back to Top |
|
| One 15 mL screw-top vial yields up to 1 liter dilution. Contains both organic and inorganic mercury to test both digestion and analysis procedures. Use with CVAA, ICP-MS or CVAFS methods. For a ng/L level mercury standard see the waste water low-level mercury standard, catalog # 931. |
|
|
| :: Hexavalent Chromium | Catalog: #658 | | Back to Top |
|
| One 15 mL screw-top vial yields up to 2 liters after dilution. Use with colorimetric or IC methods. |
|
|
| :: Uranium | Catalog: #930 | | Back to Top |
|
| One 15 mL screw-top vial yields up to 1 liter after dilution. Use with ICP-MS methods EPA 200.8, ASTM D5673-03 and Standard Methods 3125. |
|
|
| :: Vanadium | Catalog: #660 | | Back to Top |
|
| One 15 mL screw-top vial yields up to 2 liters after dilution. Use with AA, ICP-OES or ICP-MS methods. Designed to meet California ELAP requirements. |
|
|
| :: Solids Concentrate | Catalog: #5152 | | Back to Top |
|
| One 23 mL glass screw-top vial yields 1 liter after dilution. |
| | - Total Suspended Solids
- Total Dissolved Solids at 180°C
| |
|
|
| :: Nitrite | Catalog: #695 | | Back to Top |
|
| One 15 mL screw-top vial yields up to 2 liters after dilution. Use with colorimetric or ISE methods. |
|
|
| :: o-Phosphate Nutrients | Catalog: #667 | | Back to Top |
|
| One 15 mL screw-top vial yields up to 2 liters after dilution. Use with colorimetric or IC methods. |
|
|
| :: Residual Chlorine | Catalog: #696 | | Back to Top |
|
| One 2 mL flame-sealed ampule yields up to 2 liters after dilution. Use with titrimetric or colorimetric methods. For µg/L level residual chlorine QCs see the waste water low-level residual chlorine standard, catalog # 917. |
|
|
| :: Cyanide | Catalog: #983 | | Back to Top |
|
| One 15 mL screw-top vial yields up to 2 liters after dilution. Use with digestion and/or colorimetric, titrimetric or ISE methods. |
|
|
| :: Organic Carbon | Catalog: #669 | | Back to Top |
|
| One 15 mL screw-top vial yields up to 1 liter after dilution. Now includes DOC in the EPA/NELAC required range. Use for total (TOC) and dissolved (DOC) organic carbon with combustion or persulfate oxidation procedures. |
| | - Dissolved organic carbon (DOC)
| - Total organic carbon (TOC)
|
|
|
| :: Perchlorate | Catalog: #910 | | Back to Top |
|
| One 15 mL screw-top vial yields up to 2 liters after dilution. Use with IC or IC-MS methods. Call for ng/L level perchlorate QC standards. |
|
|
| :: Silica | Catalog: #785 | | Back to Top |
|
| One 60 mL poly bottle yields 1 liter after dilution. Use with colorimetric or ICP methods. |
|
|
| :: Surfactants-MBAS | Catalog: #784 | | Back to Top |
|
| One 10 mL flame-sealed ampule yields up to 2 liters after dilution. Use with EPA method 425.1. |
|
|
| :: Corrosivity | Catalog: #980 | | Back to Top |
|
| One 500 mL Whole-Volume bottle is ready to use. Use for corrosivity, calcium carbonate saturation and Langelier saturation index. |
|
|
| :: Turbidity | Catalog: #699 | | Back to Top |
|
| One 15 mL screw-top vial yielding up to 1 liter after dilution. Use with nephelometric methods. |
|
|
| :: UV 254 Absorbance | Catalog: #662 | | Back to Top |
|
| One 15 mL screw-top vial yields up to 1 liter after dilution. Use with Standard Method 5910B. Due to changes in EPA/NELAC requirements, DOC has been moved to the Organic Carbon standard shown above. |
|
|
| :: Inorganic Disinfection #1 | Catalog: #5272 | | Back to Top |
|
| One 15 mL screw-top vial yields up to 2 liters after dilution. Use with ion chromatography methods. |
|
|
| :: Inorganic Disinfection #2 | Catalog: #5262 | | Back to Top |
|
| One 15 mL screw-top vial yields up to 2 liters after dilution. Use with colorimetric, ion chromatography and ISE methods. |
|