|
| :: BTEX & MTBE in Water | Catalog: #760 | | Back to Top |
|
| One 2 mL flame-sealed ampule yields in excess of 200 mL after dilution. Use with EPA methods 602 and 8021. Contains all BTEX analytes below and Methyl tert-butyl ether (MTBE) all at 7-300 µg/L after dilution. |
| | - Benzene
- tert-Butyl methyl ether (MTBE)
- Ethylbenzene
| |
|
|
| :: Gasoline Range Organics (GRO) in Water | Catalog: #762 | | Back to Top |
|
| One 2 mL flame-sealed ampule yields up to 2 liters after dilution. Use with both purge & trap and modified EPA 8015 methods. Contains unleaded regular gasoline in the range of 200-4,000 µg/L after dilution. Also certified for all BTEX analytes. |
| | - Gasoline Range Organics (GRO)
- Benzene in GRO
- Ethylbenzene in GRO
| - Toluene in GRO
- Xylenes, total in GRO
|
|
|
| :: Diesel Range Organics (DRO) in Water | Catalog: #764 | | Back to Top |
|
| One 2 mL flame-sealed ampule yields up to 2 liters after dilution. Contains No. 2 Diesel for use with modified EPA 8015 methods. DRO is in the concentration range of 500-4,000 µg/L after dilution. |
| | - Diesel Range Organics (DRO)
| |
|
|
| :: Total Petroleum Hydrocarbons (TPH) in Water #1 | Catalog: #600 | | Back to Top |
|
| One liter Whole-Volume bottle is ready to analyze for Total Petroleum Hydrocarbons without interfering fatty acids. Use with EPA methods 413.1, 413.2, 418.1, 1664 and 5520. |
| | - Total petroleum hydrocarbons (gravimetric)
| - Total petroleum hydrocarbons (infrared)
|
|
|
| :: Total Petroleum Hydrocarbons (TPH) in Water #2 | Catalog: #601 | | Back to Top |
|
| One liter Whole-Volume bottle is ready to analyze for Total Petroleum Hydrocarbons in the presence of interfering fatty acids. Use with EPA methods 413.1, 413.2, 418.1, 1664 and 5520. |
| | - Total petroleum hydrocarbons (gravimetric)
| - Total petroleum hydrocarbons (infrared)
|
|
|
| :: Alaska BTEX in Water | Catalog: #646 | | Back to Top |
|
| One 2 mL flame-sealed ampule. Use with method AK101 for all BTEX analytes at 5-30 µg/L after dilution. |
|
|
| :: Alaska GRO in Water | Catalog: #645 | | Back to Top |
|
| One 2 mL flame-sealed ampule. Use with method AK101 for unleaded regular gasoline at 100-500 µg/L after dilution. |
| | - Gasoline Range Organics (GRO)
| |
|
|
| :: Alaska DRO in Water | Catalog: #647 | | Back to Top |
|
| One 2 mL flame-sealed ampule. Use with method AK102 for No. 2 Diesel at 800-2,300 µg/L after dilution. |
| | - Diesel Range Organics (DRO)
| |
|
|
| :: Massachusetts VPH in Water | Catalog: #566 | | Back to Top |
|
| One 2 mL flame-sealed ampule contains volatile petroleum hydrocarbon fuels (VPH) in the range 200-4,000 µg/L after dilution. Designed for Massachusetts VPH method. Certified values are provided for multiple carbon ranges as well as specific volatile aromatic compounds including MTBE. |
| | - C5-C8 Aliphatics
- C9-C12 Aliphatics
- C9-C10 Aromatics
- Benzene in VPH
- Tert-Butyl methyl ether (MTBE) in VPH
- Ethylbenzene in VPH
| - Naphthalene in VPH
- Toluene in VPH
- o-Xylene in VPH
- m&p-Xylene in VPH
- Xylenes, total in VPH
|
|
|
| :: Massachusetts EPH in Water | Catalog: #567 | | Back to Top |
|
| One 2 mL flame-sealed ampule contains extractable petroleum hydrocarbon fuels (EPH) in the range 500-4,000 µg/L after dilution. Designed for Massachusetts EPH method. Certified values are provided for multiple carbon ranges and PAH compounds. |
| | - C9-C18 Aliphatics
- C19-C36 Aliphatics
- C11-C22 Aromatics
- Acenaphthene in EPH
- Acenaphthylene in EPH
- Anthracene in EPH
- Benzo(a)anthracene in EPH
- Benzo(a)pyrene in EPH
- Benzo(b)fluoranthene in EPH
- Benzo(g,h,i)perylene in EPH
| - Benzo(k)fluoranthene in EPH
- Chrysene in EPH
- Dibenz(a,h)anthracene in EPH
- Fluoranthene in EPH
- Fluorene in EPH
- Indo(1,2,3-cd)pyrene in EPH
- 2-Methylnaphthalene in EPH
- Naphthalene in EPH
- Phenanthrene in EPH
- Pyrene in EPH
|
|
|
| :: Texas Low-Level Fuels (TPH) in Water | Catalog: #794 | | Back to Top |
|
| One 2 mL flame-sealed ampule with unleaded regular gasoline and No. 2 Diesel Fuel resulting in TPH at 5-10 mg/L after dilution. |
| | - No. 2 Diesel
- Unleaded Gasoline
| - Total Petroleum Hydrocarbons
|
|
|
| :: Texas High-Level Fuels (TPH) in Water | Catalog: #795 | | Back to Top |
|
| One 2 mL flame-sealed ampule with unleaded regular gasoline and No. 2 Diesel Fuel resulting in TPH at 20-100 mg/L after dilution. |
| | - No. 2 Diesel
- Unleaded Gasoline
| - Total Petroleum Hydrocarbons
|
|
|
| :: HEM/SGT-HEM | Catalog: #519 | | Back to Top |
|
| One 5 mL flame-sealed ampule yields up to 2 liters after dilution. Use with EPA method 1664 to measure hexane extractable material (HEM) and silica gel treated-HEM. Contains both hexadecane and stearic acid. The Perfect Partner™ QC for State of Washington method 1664 TPH PTs. |
|
|
| :: Wisconsin Gasoline Range Org (GRO/PVOC) in Water | Catalog: #773 | | Back to Top |
|
| One 2 mL flame-sealed ampule with ten gasoline range volatile synthetic organic compounds at 200-600 µg/L after dilution. Use with the Wisconsin GRO/PVOC method. |
| | - Gasoline Range Organics (GRO)
- Benzene
- tert-Butyl methyl ether (MTBE)
- Ethylbenzene
- Toluene
| - 1,2,4-Trimethylbenzene
- 1,3,5-Trimethylbenzene
- m&p-Xylene
- o-Xylene
- Xylenes, total
|
|
|
| :: Wisconsin Diesel Range Organics (DRO) in Water | Catalog: #772 | | Back to Top |
|
| One 2 mL flame-sealed ampule with ten diesel range synthetic organic compounds at 200-600 µg/L after dilution. Use with the Wisconsin DRO method. |
| | - Diesel range organics (DRO)
| |
|