SEARCH:       
   
  Home
  Links
:: Water

:: BTEX & MTBE in WaterCatalog: #760Back to Top

One 2 mL flame-sealed ampule yields in excess of 200 mL after dilution. Use with EPA methods 602 and 8021. Contains all BTEX analytes below and Methyl tert-butyl ether (MTBE) all at 7-300 µg/L after dilution.
  • Benzene
  • tert-Butyl methyl ether (MTBE)
  • Ethylbenzene
  • Toluene
  • Xylenes, total

:: Gasoline Range Organics (GRO) in WaterCatalog: #762Back to Top

One 2 mL flame-sealed ampule yields up to 2 liters after dilution. Use with both purge & trap and modified EPA 8015 methods. Contains unleaded regular gasoline in the range of 200-4,000 µg/L after dilution. Also certified for all BTEX analytes.
  • Gasoline Range Organics (GRO)
  • Benzene in GRO
  • Ethylbenzene in GRO
  • Toluene in GRO
  • Xylenes, total in GRO

:: Diesel Range Organics (DRO) in WaterCatalog: #764Back to Top

One 2 mL flame-sealed ampule yields up to 2 liters after dilution. Contains No. 2 Diesel for use with modified EPA 8015 methods. DRO is in the concentration range of 500-4,000 µg/L after dilution.
  • Diesel Range Organics (DRO)

    :: Total Petroleum Hydrocarbons (TPH) in Water #1Catalog: #600Back to Top

    One liter Whole-Volume bottle is ready to analyze for Total Petroleum Hydrocarbons without interfering fatty acids. Use with EPA methods 413.1, 413.2, 418.1, 1664 and 5520.
    • Total petroleum hydrocarbons (gravimetric)
    • Total petroleum hydrocarbons (infrared)

    :: Total Petroleum Hydrocarbons (TPH) in Water #2Catalog: #601Back to Top

    One liter Whole-Volume bottle is ready to analyze for Total Petroleum Hydrocarbons in the presence of interfering fatty acids. Use with EPA methods 413.1, 413.2, 418.1, 1664 and 5520.
    • Total petroleum hydrocarbons (gravimetric)
    • Total petroleum hydrocarbons (infrared)

    :: Alaska BTEX in WaterCatalog: #646Back to Top

    One 2 mL flame-sealed ampule. Use with method AK101 for all BTEX analytes at 5-30 µg/L after dilution.
    • Benzene
    • Ethylbenzene
    • Toluene
    • Xylenes, total

    :: Alaska GRO in WaterCatalog: #645Back to Top

    One 2 mL flame-sealed ampule. Use with method AK101 for unleaded regular gasoline at 100-500 µg/L after dilution.
    • Gasoline Range Organics (GRO)

      :: Alaska DRO in WaterCatalog: #647Back to Top

      One 2 mL flame-sealed ampule. Use with method AK102 for No. 2 Diesel at 800-2,300 µg/L after dilution.
      • Diesel Range Organics (DRO)

        :: Massachusetts VPH in WaterCatalog: #566Back to Top

        One 2 mL flame-sealed ampule contains volatile petroleum hydrocarbon fuels (VPH) in the range 200-4,000 µg/L after dilution. Designed for Massachusetts VPH method. Certified values are provided for multiple carbon ranges as well as specific volatile aromatic compounds including MTBE.
        • C5-C8 Aliphatics
        • C9-C12 Aliphatics
        • C9-C10 Aromatics
        • Benzene in VPH
        • Tert-Butyl methyl ether (MTBE) in VPH
        • Ethylbenzene in VPH
        • Naphthalene in VPH
        • Toluene in VPH
        • o-Xylene in VPH
        • m&p-Xylene in VPH
        • Xylenes, total in VPH

        :: Massachusetts EPH in WaterCatalog: #567Back to Top

        One 2 mL flame-sealed ampule contains extractable petroleum hydrocarbon fuels (EPH) in the range 500-4,000 µg/L after dilution. Designed for Massachusetts EPH method. Certified values are provided for multiple carbon ranges and PAH compounds.
        • C9-C18 Aliphatics
        • C19-C36 Aliphatics
        • C11-C22 Aromatics
        • Acenaphthene in EPH
        • Acenaphthylene in EPH
        • Anthracene in EPH
        • Benzo(a)anthracene in EPH
        • Benzo(a)pyrene in EPH
        • Benzo(b)fluoranthene in EPH
        • Benzo(g,h,i)perylene in EPH
        • Benzo(k)fluoranthene in EPH
        • Chrysene in EPH
        • Dibenz(a,h)anthracene in EPH
        • Fluoranthene in EPH
        • Fluorene in EPH
        • Indo(1,2,3-cd)pyrene in EPH
        • 2-Methylnaphthalene in EPH
        • Naphthalene in EPH
        • Phenanthrene in EPH
        • Pyrene in EPH

        :: Texas Low-Level Fuels (TPH) in WaterCatalog: #794Back to Top

        One 2 mL flame-sealed ampule with unleaded regular gasoline and No. 2 Diesel Fuel resulting in TPH at 5-10 mg/L after dilution.
        • No. 2 Diesel
        • Unleaded Gasoline
        • Total Petroleum Hydrocarbons

        :: Texas High-Level Fuels (TPH) in WaterCatalog: #795Back to Top

        One 2 mL flame-sealed ampule with unleaded regular gasoline and No. 2 Diesel Fuel resulting in TPH at 20-100 mg/L after dilution.
        • No. 2 Diesel
        • Unleaded Gasoline
        • Total Petroleum Hydrocarbons

        :: HEM/SGT-HEMCatalog: #519Back to Top

        One 5 mL flame-sealed ampule yields up to 2 liters after dilution. Use with EPA method 1664 to measure hexane extractable material (HEM) and silica gel treated-HEM. Contains both hexadecane and stearic acid. The Perfect Partner™ QC for State of Washington method 1664 TPH PTs.
        • HEM
        • SGT-HEM

        :: Wisconsin Gasoline Range Org (GRO/PVOC) in WaterCatalog: #773Back to Top

        One 2 mL flame-sealed ampule with ten gasoline range volatile synthetic organic compounds at 200-600 µg/L after dilution. Use with the Wisconsin GRO/PVOC method.
        • Gasoline Range Organics (GRO)
        • Benzene
        • tert-Butyl methyl ether (MTBE)
        • Ethylbenzene
        • Toluene
        • 1,2,4-Trimethylbenzene
        • 1,3,5-Trimethylbenzene
        • m&p-Xylene
        • o-Xylene
        • Xylenes, total

        :: Wisconsin Diesel Range Organics (DRO) in WaterCatalog: #772Back to Top

        One 2 mL flame-sealed ampule with ten diesel range synthetic organic compounds at 200-600 µg/L after dilution. Use with the Wisconsin DRO method.
        • Diesel range organics (DRO)