PFAS

Stay current with evolving PFAS regulations

Per- and Polyfluoroalkyl Substances (PFAS) are widely used in industrial and consumer products. These man-made chemicals migrate to water, air, soil, human and animal tissue, and food products and due to their chemical nature, they remain and accumulate in the environment.  They have increasingly become of concern for health reasons, therefore leading to calls for more stringent regulations and monitoring. To that end, environmental testing laboratories are being asked to analyze for more species of PFAS at lower concentrations.

PFAS Secondary Source Standards

The scarcity of PFAS standard suppliers poses a challenge for laboratories. To circumvent this challenge, laboratories can create their own standards, but this process can be time-consuming and prone to errors. Waters ERA’s NEW STANDARDS address both challenges by providing a reliable secondary source for routine quality control as a straightforward solution for verification without the need for additional dilutions. With a comprehensive list of EPA Method 1633 and 533/537 analytes, our standards ensure thorough verification at concentrations precisely calibrated to match PFAS method calibration curves.

Our new PFAS Secondary Source Standard products, Items PFAS10001 and PFAS10002, are available to order now. Shipments will begin May 13, 2024.
Wastewater/Solids

Sample Description

One 2 mL flame-sealed ampule with 1.5 mL of PFAS standard containing 44 analytes at 25-625 ng/mL. The standard is suitable for matrices to include, but not limited to, wastewater and solids and compatible with methods EPA 1633, EPA 8327, ASTM D8421-21, ASTM D7979 and other comparable methods.


Secondary Source Standard

Item PFAS10001 – PFAS Secondary Source Std, Wastewater/Solids

Analytes

25-625 ng/mL
44 analytes

Suitable Methods

EPA 8327, ASTM D7979, EPA 1633, ASTM D8421-21, EPA SW-846, Method 8327 and other comparable LC/MS/MS methods

Drinking Water

Sample Description

One 2 mL flame-sealed ampule with 1.5 mL of PFAS standard containing 29 analytes at 50 ng/mL. The standard is suitable for matrices to include, but not limited to, drinking water and compatible with methods EPA 533, EPA 537, EPA 537.1 and other comparable methods.


Secondary Source Standard

Item PFAS10002 – PFAS Secondary Source Std, Drinking Water

Analytes

50 ng/mL
29 analytes

Suitable Methods

EPA 533, EPA 537, EPA 537.1 and other comparable LC/MS/MS methods



Streamlining PFAS PT and CRM portfolio for you

The world of PFAS continues to evolve with the introduction of new methods. Waters ERA, your source for method-appropriate PFAS PT and CRM products, is resolute on keeping pace with your needs by focusing our product line and expanding study availability. The NEWEST member of our PFAS product line is certified for the 40 analytes required by EPA Method 1633 for soil. Your lab can add accreditation, demonstrate analyst competency, and document your commitment to quality for this new method.
  • PFAS in Soil, Soil PT Item 465
  • PFAS in Soil, Soil CRM Item 603
  • PFAS in Soil, Soil QR Item 603QR

ERA’s recent additions to our PFAS product line, for both wastewater and drinking water, will assist your laboratory in achieving accreditation for current PFAS Methods: EPA Methods 533, 537, 537.1, 1633 and ASTM Method D8421-21.
  • PFAS in Drinking Water, WS PT Item 959
  • PFAS in Drinking Water, WS CRM Item 733
  • PFAS in Drinking Water, WS QR Item 733QR
AND
  • PFAS in Wastewater, WP PT Item 599
  • PFAS in Wastewater, WP CRM Item 404
  • PFAS in Wastewater, WP QR Item 404QR

As a NELAC and ISO 17043 accredited PT provider, we deliver the products you need to be confident about your data.

Order our PFAS Products
Wastewater

Sample Description

One 2 mL flame-sealed ampule yields in excess of 1.5 L after dilution. The diluted standard is certified for 44 analytes spiked at 20--400 ng/L . The sample is designed for LC/MS/MS methods for analyzing wastewater, specifically EPA Method 1633, ASTM Method D8421-21, and SW-846 Method 8327. This product is a replacement for 598 (PT), 403 (CRM), and 403QR (QR).





Proficiency Test Sample

Item 599 - PFAS in Wastewater, WP PT
Quarterly study

Certified Reference Material 

Quality control standard

Item 404 - PFAS in Wastewater, WP CRM

QuiK Response

PT on your schedule without waiting for the next study

Item 404QR - PFAS in Wastewater, WP QR


Analytes

Varying concentrations

44 analytes

Suitable Methods

EPA 8327, ASTM D7979, EPA 1633, ASTM D8421-21, EPA SW-846 Method 8327

Drinking Water

Sample Description

One 2 mL flame-sealed ampule yields in excess of 1.5 L after dilution. The diluted standard is certified for 32 analytes spiked at 10-200 ng/L . The sample is designed for LC/MS/MS methods for analyzing potable water, specifically EPA Methods 533, 537 and 537.1. This product is a replacement for PFAS Drinking Water and PFAS Groundwater & Surface Water products: 960 (PT), 735 (CRM), 735QR (QR), 929 (PT), 731 (CRM) and 731QR (QR).


Proficiency Test Sample

Item 959 – PFAS in Drinking Water, WS PT
Quarterly study

Certified Reference Material 

Quality control standard

Item 733 – PFAS in Drinking Water, WS CRM

QuiK Response

PT on your schedule without waiting for the next study

Item 733QR – PFAS in Drinking Water, WS QR

Analytes

Varying concentrations

32 analytes

Suitable Methods

EPA 533, EPA 537, EPA 537.1




Soil

Sample Description

One flame-sealed ampule containing 10 g of soil. The standard is certified for 40 analytes and will be spiked with a subset of a minimum of 24 analytes at 5-50 ug/kg. The sample is designed for LC/MS/MS methods for analyzing soil, specifically EPA Method 1633, EPA Method 8327 and DoD/DoE QSM Table B-15. This product is a replacement for 462 (PT), 604 (CRM) and 604QR (QR).





Proficiency Test Sample

Item 465 - PFAS in Soil, Soil PT
Quarterly study

Certified Reference Material 

Quality control standard

Item 603 - PFAS in Soil, Soil CRM

QuiK Response

PT on your schedule without waiting for the next study

Item 603QR - PFAS in Soil, Soil QR

Analytes

Varying concentrations

Subset of 40 analytes
(Minimum of 24 analytes)

Suitable Methods

Existing and Draft

EPA 1633, EPA 8327, DoD/DoE QSM Table B-15




Achieve ultimate sensitivity and reproducibility for your PFAS workflow

Waters and ERA are dedicated to helping you meet regulatory requirements and establish sensitive, robust and reproducible workflows in your lab.

Learn more about Waters analytical systems


Highlighted Products

For a complete list of related resources please visit our store.
PFAS in Soil, Soil PT
Item No. 465


Loading
Loading